Description
Sealed Bids for the construction of the Kemmer Rd 800-794 Beaverton Intertie, Project No. C12731 (Project) for Tualatin Valley Water District (Owner) will be accepted by Heather Speight, Procurement and Contracts Administrator, via Equity Hub’s Bid Locker at https://bidlocker.us/details/3322_Kemmer_Rd_Intertie (Bid Locker), until 2:00 p.m. local time on Wednesday, May 17, 2023 (Bid Closing Time). Bidders must sign up with Bid Locker at https://bidlocker.us/a/tvwd/BidLocker before being allowed to submit a bid. There is no cost to register. Any bids received after the Bid Closing Time will not be considered.
Registration with Bid Locker requires a correctly completed Confidentiality Agreement, which is available through the registration process. Following completion of the requested vendor information and upload of the Confidentiality Agreement, the vendor profile will be sent for a manual approval. Please allow one business day for your vendor profile to be approved. If it has not been approved within one business day, or if you have questions about this process, please contact bidsandproposals@tvwd.org. Bidders are advised to ensure that their Bid Locker vendor profile is active and approved a minimum of three business days prior to the Bid Closing Time to prevent any issues with submitting a bid on time.
Bids received by the Bid Closing Time will be publicly opened and read aloud immediately thereafter on a conference call at (971) 300-4841, phone conference ID 495 168 916#.
The Bidder is required to submit a First Tier Subcontractor Disclosure Form (First Tiers), as described by ORS 279C.370. The First Tiers must be submitted to Bid Locker within two hours of the Bid Closing Time. The Owner must reject a bid if the Bidder fails to submit the First Tiers to Bid Locker within two hours of the Bid Closing Time. Original copies of the Bid Security must be submitted to Owner within five business days of the Bid Closing Time as prescribed in Section 00 21 13.
The proposed work for the Project consists of furnishing required labor, equipment, and materials for construction of the following:
· Approximately 1,500 linear feet of 24-inch ductile iron restrained-joint water piping with ductile iron fittings and polyethylene encasement.
· One hot tap connection, multiple air release and blow off assemblies, 2” copper jumper connection from parallel Tualatin Valley Water District 920 pressure zone piping to new 24-inch piping, connection to intertie vault stub-out by others, testing and special inspection, associated surface restoration, clean-up, traffic control, erosion control, and incidental related work as described in the Contract Documents.
Limited Notice to Proceed will be issued immediately upon contract execution. Notice to Proceed will be issued once Contractor has received all material. Material lead times are anticipated to be up to eight months. All work is to be completed (Substantial Completion) within 60 calendar days of the Notice to Proceed.
Bid Documents may be obtained electronically from Bid Locker or in either electronic or hard copy format by contacting:
Contractor Plan Center, Inc.
5468 SE International Drive
Milwaukie, OR 97222
Phone: (503) 650-0148
Fax: (503) 650-8273
E-mail: megan@contractorplancenter.com
If a potential Bidder obtains the Bid documents from Contractor Plan Center, the Bidder is still responsible for registering with Bid Locker to submit their bid.
Addenda will be published to Bid Locker. Bidders who download bid packages from Bid Locker will automatically be notified via email when addenda are published. It is the responsibility of the Bidder to obtain all addenda. Bidders are responsible for the cost of obtaining and/or printing the Bid Documents. The Bidder, including subcontractors, will also be responsible for signing a confidentiality agreement prior to obtaining the documents. Return of the documents is not required, and the amount paid for the Bid Documents is nonrefundable.
There will not be a pre-bid conference for this Project.
Contractors must be qualified in accordance with the applicable parts of ORS 279 to enter into a contract with the Owner for public work in Oregon. Bidders are required to complete and submit with their bid Section 00 45 13, “Statement of Bidder’s Qualifications”. The Owner will investigate and determine if the qualifications of the apparent low bidder meet the minimum requirements as part of its evaluation of the lowest responsive and responsible bid.
No bid will be received or considered by the Owner unless the Bid Form contains, or is accompanied by, a statement by the Bidder as a part of the bid that the provisions required by ORS 279C.800 through 279C.870 pertaining to prevailing wages are included in this Contract. Contractor licensing under ORS 468A.720 for asbestos abatement is not a requirement of this Project. Each bid must contain a statement as to whether the Bidder is a resident bidder as defined in ORS 279A.120. Each bid must contain a statement as to whether the Bidder is registered with the Oregon Construction Contractors Board in accordance with the provisions of ORS 279C.365.
Bids must be submitted on the prescribed forms and must be accompanied by a certified check or bid bond executed in favor of the Tualatin Valley Water District in an amount not less than ten (10) percent of the amount bid. The successful Bidder will be required to furnish the necessary additional bond(s) for the faithful performance of the Contract as prescribed in the Contract Documents.
The Owner reserves the right to reject all bids not in compliance with all prescribed public contracting procedures and requirements, including bidder responsibility under ORS 279C.375(3)(b), and may reject for good cause all bids upon the Owner’s finding that it is in the Owner’s or the public’s best interest to do so. The Owner reserves the right to waive informalities and to award a Contract to the qualified lowest responsive and responsible Bidder.
For more information regarding this Project contact Heidi Springer, Senior Engineer with Tualatin Valley Water District at heidi.springer@tvwd.org.
Published April 17, 2023 and April 19, 2023
Line Items
This solicitation has the following line items for which you can submit a bid. Please review the bidding instructions in the bid documents for information on these line items:
Item No | Item | Unit of Measure | Quantity | Required? |
---|---|---|---|---|
1 | Mobilization | LS | 1.00 | |
2 | Health and Safety | LS | 1.00 | |
3 | Temporary Traffic Control | LS | 1.00 | |
4 | Erosion control | LS | 1.00 | |
5 | Construction survey and staking | LS | 1.00 | |
6 | Over-Excavation and Backfill | CY | 50.00 | |
7 | Boulder Excavation, Haul, and Disposal | CY | 50.00 | |
8 | Rock Excavation, Haul, and Disposal | CY | 250.00 | |
9 | 12-inch Zinc-Coated Ductile Iron Pipe, Restrained | LF | 20.00 | |
10 | 16-inch Zinc-Coated Ductile Iron Pipe, Restrained | LF | 20.00 | |
11 | 24-inch Zinc-Coated Ductile Iron Pipe, Restrained | LF | 1568.00 | |
12 | 16-inch Small Ductile Iron Zinc-Coated Fitting | EA | 1.00 | |
13 | 24-inch Small Ductile Iron Zinc-Coated Fitting | EA | 8.00 | |
14 | 16-inch Large Ductile Iron Zinc-Coated Fitting | EA | 1.00 | |
15 | 24-inch Large Ductile Iron Zinc-Coated Fitting | EA | 4.00 | |
16 | 16-inch Butterfly Valve | EA | 2.00 | |
17 | 24-inch Butterfly Valve | EA | 3.00 | |
18 | 2-inch Combination Air Release Valve Assembly | EA | 1.00 | |
19 | 6-inch Blow Off Assembly | EA | 2.00 | |
20 | 2-inch Blow Off Assembly | EA | 1.00 | |
21 | 12" x 12" Hot Tap Assembly | EA | 1.00 | |
22 | Connection to Existing Water System | EA | 1.00 | |
23 | 1" Jumper Connection Assembly | LS | 1.00 | |
24 | Pipeline Cleaning, Testing, and Disinfection | LS | 1.00 | |
25 | Locate Test Wire Station | EA | 3.00 | |
26 | Permanent Asphalt Concrete Trench Restoration | TN | 710.50 | |
27 | 2-inch Grind and AC Pavement Inlay | SY | 2091.00 | |
28 | Striping Restoration | LF | 3136.00 | |
29 | Miscellaneous Surface Restoration | LS | 1.00 |
Attachments
This project has the following solicitation documents.
You will need to:
- Be logged into Bid Locker
- Be registered with Tualatin Valley Water District
Vendor Questions and Answers
Submitted Questions About This Bid
There are no questions that have been answered and posted by Tualatin Valley Water District.
For Questions or Additional Information, Contact:
Name: Heather Speight
Email: bidsandproposals@tvwd.org
Planholders
Planholders
These are the vendors who have downloaded the solicitation documents:
Business | When |
---|---|
Compass Land Surveyors | Apr 20, 2023 |
Consolidated Supply Co | Apr 17, 2023 |
Core And Main | May 9, 2023 |
Correct Equipment | May 2, 2023 |
Emery & Sons Construction Group, LLC | Apr 17, 2023 |
James W. Fowler Co. | Apr 18, 2023 |
K&E Excavating, Inc. | Apr 19, 2023 |
Kerr Contractors Oregon, LLC | Apr 17, 2023 |
Moore Excavation Inc. | Apr 24, 2023 |
Trench Line Excavation, Inc. | Apr 19, 2023 |
Commodity Codes and Solicitation Change History
Commodity Codes (NIGP):
- 913-60
- Construction, Water System, Plants, Main And Service Line
Changes to This Listing:
Change | |
---|---|
The approximate price range has changed. The following bid documents were added: Kemmer Rd Intertie Clarification 1.pdf |
Apr 19, 2023 |
The following bid documents were added: Kemmer Rd Intertie Addendum 1.pdf |
May 3, 2023 |
The following bid documents were added: Kemmer Rd Intertie Addendum 2.pdf |
May 9, 2023 |
The following bid documents were added: Kemmer Rd Intertie Addendum 3.pdf |
May 11, 2023 |
The following bid documents were added: Kemmer Rd Intertie Addendum 4.pdf |
May 12, 2023 |
No changes detected. |
May 17, 2023 |
About Tualatin Valley Water District
Contracting with TVWD
TVWD is a special district, established to provide drinking water, and is governed by an elected Board of Commissioners. Because some of the information in our solicitations is confidential and protected under US law, all vendors are required to complete a Confidentiality Agreement prior to their TVWD Bid Locker profile being approved. This approval is a manual process. Please allow one business day for approval and follow any emailed instructions received. TVWD is not responsible for vendors who cannot download and/or submit solicitation responses due to vendor profiles that are not approved.
Public agencies with questions about a solicitation should call 503.848.3055 or email bidsandproposals@tvwd.org for information. Vendors who reach out directly will be redirected to the instructions in the specific solicitation or other emailed instructions.
Share:
Your submitted questions |
---|